Document
Flyer_inductar CS cube
Contenu du document
Advanced carbon and sulfur determination
High sensitivityHigh data qualityExtreme durability Great flexibility
Experience the new level
of accurate and
easy to use CS analysis
KEY FEATURES
• Minimized dust and debris make
tedious cleaning operations needless
• Semi-automated or fully-automated with up to 89 sample positions for
secure and unattended 24?/?7 operation
• Solid-state technology for long-living induction furnace
• Gas-tight clamp connection system ensures easy and tool-free
maintenance
• Intuitive and feature-rich software makes operator‘s life incredibly simple
Sample input from top
Innovative crucible
geometry
2 wide-range IR detectors
Drying agents with indicator
Efficient oxidation
Tool-free maintenance
Top-down oxygen gas flow
Integrated camera
(optional)
89 position autosampler
Heated dust filter
Solid-state induction furnace
Elementar developed a CS analyzer which
combines highly accurate data with easy
to use, clean, and automated processes.
Experience the new level of carbon and
sulfur determination in metals and inorganic
materials. The new inductar
? CS cube is full of
innovative and advanced ideas to make
CS analysis easy to use and more reliable.
O2
FurnaceFurnace Combustion
H
2O trap
SO
2?/?CO oxidation SO
3 trap
Dust trap
CLEAN COMBUSTION
A cleaner combustion than any system
built in the past is achieved with this new
technology. Our innovative construction
principle in combination with the high
ceramic crucibles reduces contamination of
the system by dust and debris to an absolute
minimum. This is achieved by a top-down
oxygen gas stream. With this approach a
unique sheath gas flow is established, which
minimizes adhesion of dust and debris at
the combustion tube. Dust and debris, which
are formed during combustion process, are
captured inside the ceramic crucibles. This
set-up allow for parts like combustion tube
or dust filter to be cleaned less often and of
course measure more accurately.
CS ANALYSIS
In a pure oxygen atmosphere the sample is
introduced to the induction furnace. Unlike
conventional systems, the inductar series
feeds the sample from the top. The high
temperature in the furnace converts traces
of sulfur and carbon from the sample into
sulfur dioxide, carbon monoxide, and
carbon dioxide. After detection of sulfur
dioxide by use of an IR detector, carbon
monoxide and sulfur dioxide are oxidized
to carbon dioxide and sulfur trioxide. In
the next step sulfur trioxide is removed
from the gas flow. Finally a second IR
detector determines the carbon dioxide
concentration.
KEY FEATURES
• Minimized dust and debris make
tedious cleaning operations needless
• Semi-automated or fully-automated with up to 89 sample positions for
secure and unattended 24?/?7 operation
• Solid-state technology for long-living induction furnace
• Gas-tight clamp connection system ensures easy and tool-free
maintenance
• Intuitive and feature-rich software makes operator‘s life incredibly simple
COMBUSTION
DETECTION
IR
SO
2
IR
CO
2
DETECTION
Innovative ideas
Innovative ideas combined with state-of-the-art
technologies let the inductar CS cube clearly stand out
from the crowd. The new construction design captures
dust and debris within the ceramic crucibles. Moreover,
the energy-eflcient solid-state induction furnace
enables high temperatures up to 2,000?C. Combined with
high-performance detectors, the inductar CS cube shows
excellent accuracy and lowest possible limit of detection.
Reliable results
The highly optimized combustion process – a well-known
highlight of all Elementar instruments – always guarantees
reliable and accurate results. High quality materials, well
structured construction design, and long-living components
make the system unrivaled, robust, and durable.
SAMPLER
Automated analysis
The fast and precise autosampler with its innovative
robotic arm (patent pending) allows unattended
24fl/fl7 operation. The sequence of all 89 sample positions
is user congurable and can be changed at any time.
Automation is further accomplished by automatic weight
transfer from balance, barcode reader support and easy
LIMS integration. The inductar CS cube is controlled via an
intuitive, feature-rich, multi-language software. It is easy
to use and congurable to fulll all requirements in R & D,
quality control, and high-throughput laboratories.
Unsurpassed system uptime
The inductar CS cube is developed for unsurpassed
user convenience and maximum robustness for
24fl/fl7 operation. The proprietary solid-state technology
for the induction furnace ensures a virtually unlimited
lifetime of components. This nally makes a frequent
exchange of oscillator tubes obsolete. By design, no
tedious cleaning operation is required to handle dust and
debris. Maintenance work, which is a tool-free task, is
performed within seconds.
Advanced carbon and sulfur analysis
for inorganic materials
IDEAL SOLUTION FOR
• Steelworks
• Foundries
• Automotive industry
• Cement industry
• Ceramic industry
SAMPLE TYPES ANALYZED
• Steel
• Cast iron
• Non-ferrous metals
• Cements
• Other inorganic materials
Art-No. 05 005 065, 04?/?2019 A
Outstanding robustness and
longevity thanks to state-of-
the-art technology.
Outstanding precision and accuracy
through high performance combustion.
Longterm stability of calibration.
Outstanding sensitivity thanks
to high performance, state-
of-the-art technology. Wide range of materials
analyzable. Upgradeable
at any time.
EASY TO USE EQUIPMENT
The inductar CS cube is the latest in fast carbon/sulfur
analysis for metal species. With an accessible yet high-
tech driven design, this system is built to reduce main-
tenance efforts and maximize combustion tube lifetime.
Other reagent lifetimes are monitored by automated
indicators within our advanced software. The tool-free
clamp connection system ensures reliable leak-tight seals
while operating the instrument. Thus customers can enjoy
smooth sample analysis with high sample throughput.
QUALITY YOU CAN TRUST
Our consumables and spare parts are designed to meet
the highest quality standards and reliability. They are
certified and validated in accordance with international
norms and standards. We do not compromise on quality
of our parts and chemicals – allowing us to guarantee the
remarkable lifetime of our instruments.
SAMPLE CARBON [%] SULFUR [%]
MARAGING STEEL 0.0014
± 0.0001 0.0025
± 0.0001
CARBON STEEL 0.1738
± 0.0010 0.1309
0.0022
FERRO MANGANESE 0.3469
± 0.0011 0.0045
± 0.0008
CAST IRON 2.8301
± 0.0073 0.2420
± 0.0006
WHITEHEART MALLEABLE IRON3.2023
± 0.0067 0.2430
± 0.0035
T iO
2 BASED PIGMENT 0.0037
± 0.0001 0.0003
± 0.0001
PORTLAND CEMENT 0.1007
± 0.0008 1.9092
± 0.0270
S iC BASED AUTOMOTIVE
CATALYST 0.2340
± 0.0009 -
ANTI-PIPING COMPOUND 6.3955
± 0.0681 -
High sensitivity
High data quality Extreme durability Great flexibility
Elementar Analysensysteme GmbH
Elementar-Straße 1 · 63505 Langenselbold (Germany)
Phone: +49 (0) 6184 9393-0 | info@elementar.de | www.elementar.de Elementar – your partner for excellent elemental analysis
Elementar is the world leader in high performance analysis of organic and inorganic elements.
Continuous innovation, creative solutions and comprehensive support form the foundation of the Elementar
brand, ensuring our products continue to advance science across agriculture, chemical, environmental,
energy, materials and forensics markets in more than 80 countries.
Entreprise(s) concernée(s) :
Produit(s) concerné(s) :
Date d'upload du document :
mardi 9 novembre 2021